A high aromatic hydrocarbon solvent designed for general purpose clean-up and preparation procedures prior to the installation of ARDEX Butynol Membranes.
A synergistic blend of high aromatic hydrocarbon solvents.
PRODUCT DESCRIPTION
A synergistic blend of high aromatic hydrocarbon solvents.
PACKAGING
20 Litres
SHELF LIFE
2 years
COVERAGE
Not applicable
DRYING TIME
Approx. 20-30 minutes at @ 23?C.
APPLICATION
For preparation of Butynol membranes surfaces
should be cleaned by scouring with ARDEX WPM 290
(Shelter WA 98) solvent.
CLEAN UP
Wash skin that has come in contact with ARDEX WPM 290
(Shelter WA 98) solvent with warm water and detergent.
Application of skin moisturisers is recommended after use.
SAFETY PRECAUTIONS
ARDEX WPM 290 is hazardous and a dangerous goods.
It is highly flammable and irritating to eyes and skin. No
smoking. Harmful if swallowed. Keep away from sources
of ignition. Keep container tightly closed and in a well
ventilated place. In case of contact with eyes rinse with
plenty of water and contact a doctor or Poisons
Information Centre.
ADDITIONAL INFORMATION IS LISTED IN THE MATERIAL
SAFETY DATA SHEET.
ARDEX WA 98 ADHESIVE
(ARDEX WA 98 ADHESIVE)
BUTYNOL ADHESIVE
Specially formulated adhesive for all Butynol applications
including broadspan bonding and lap jointing in nonaggressive
or non-immersed condition exposure.
Supplied in 20L steel pails (approx. 20kg).
4 and 1 litre cans.
The standard contact brushing spray grade and rolling
adhesive for fixing to the substrate and for laps not subject
to periodic ponding.
SAFETY PRECAUTIONS
ARDEX WA 98 is hazardous and a dangerous goods.
It is highly flammable and harmful if swallowed. It is
irritating to the eyes and skin and may cause sensitisation
by skin contact. Keep container tightly closed and in a well
ventilated place. Take off immediately all contaminated
clothing. In case of contact with eyes rinse with plenty of
water and contact a doctor or Poisons Information Centre.
ADDITIONAL INFORMATION IS LISTED IN THE MATERIAL
SAFETY DATA SHEET.
ARDEX SEAM TAPE
ARDEX Seam Tape is an uncured butyl cold gum tape for
use in conjunction with ARDEX Seam Primer for bonding
Butynol lap joints. ARDEX Seam Tape is suitable for laps
that are likely to be subjected to periodic ponding only
not suitable for continuous immersion conditions.
For continuous immersion joints must be fusion welded.
Supplied in 50mm x 30.5m rolls (6 to a carton).
ARDEX PRESSURE SEAL
Designed to seal the edges of ARDEX Butynol or ARDEX
Torch Applied Bitumen (Shelterbit) Membranes and ARDEX
SBS Self Adhesive (Shelterseal) Membranes where no
existing cavity flashing or dampcourse has been installed.
PRODUCT DESCRIPTION
3 metre lengths of specially formed aluminium strip.
INSTALLATION
The ARDEX Pressure Seal is mechanically fixed through the
top edge of the membrane at 500mm intervals. The
uppermost edge of the strip is then sealed with ARDEX
Butynol Sealant along the profile provided.
PACKAGING
Packs containing 10 x 3 metre lengths.
ARDEX WPM 299 SEAM PRIMER
A water resistant primer adhesive used with seam tape
for general lap bonding.
ARDEX WPM 299 Seam Primer is suitable for laps that are
likely to be subjected to periodic ponding only not
suitable for continuous immersion conditions. For
continuous immersion joints must be fusion welded.
Important: Temperature and Humidity
The evaporation of any solvent adhesive system causes
a drop in temperature at the interface. At times of high
humidity this can result in a micro molecular water layer
at the interface which will result in a failure to bond falsely
attributed to adhesive failure. Fixing should not proceed
under these circumstances.
NOTES
1. In cases of extreme absorbency a priming coat of
full strength ARDEX WA 98 adhesive may assist water
shedding and absorption. However a follow up coat
of full strength adhesive for full bonding should not be
proceeded with under four hours thus allowing full
evaporation of solvents absorbed into the substrate.
Primers must be time dried not touch dried.
2. As new substrate materials continually appear on the
market consult ARDEX for approval of their use with
Butynol.
3. Where periodic ponding is likely and on roofs with a
slope of 5° or less ARDEX Seam Tape and ARDEX WPM
299 Seam Primer must be used on all joints.
4. Laps can be formed on roofs with a pitch greater than
5° with normal brush grade substrate ARDEX WA 98
adhesive. Laps must be solvent wiped with ARDEX WPM
290 solvent prior to applying adhesive. They must however
at all times drain dry and have no periodic ponding.
5. Do not use in temperatures less than 6°C.
FLAMMABILITY
ARDEX WPM 299 Seam Primer gives off highly flammable
vapour. Keep well away from heat sparks and open flame.
Keep closed when not in use.
LIMITATIONS
Primer should be used with appropriate mask and breathing
apparatus in areas of poor ventilation and/or air flow.
SAFETY PRECAUTIONS
ARDEX WPM 299 is hazardous and a dangerous goods.
It is highly flammable and harmful if swallowed. It is
irritating to the eyes and skin and may cause sensitisation
by skin contact. Keep container tightly closed and in a well
ventilated place. Take off immediately all contaminated
clothing. In case of contact with eyes rinse with plenty of
water and contact a doctor or Poisons Information Centre.
ADDITIONAL INFORMATION IS LISTED IN THE MATERIAL
SAFETY DATA SHEET.
ARDEX BUTYNOL SEALANT
Description
ARDEX Butynol Sealant has been specially designed and
formulated for sealing Butynol flashings into chases as
found in Building and Construction. Butynol Sealant gives
excellent adhesion and sealant properties to both Butynol
Membranes and building substrates.
FLAMMABILITY
ARDEX Butynol Sealant gives off highly flammable vapour.
Keep well away from heat sparks and open flame. Keep
closed when not in use.
DIRECTIONS
Once the Butynol Membrane has been fixed into place
apply an even bead of Butynol Sealant into the chase
which should be properly prepared by ensuring all
surfaces are clean dry and sound. Tool the sealant bead
to ensure there are no voids gaps or air pockets and that
the bead has a neat and flush finish.
TACK FREE TIME
Approx. 24 hours depending on temperature conditions
can be painted within 4 to 6 days.
FULL CURE TIME
4-6 days depending on temperature conditions.
CLEAN UP
Clean tools etc. with mineral turpentine.
COLOUR
Black
LIMITATIONS
Sealant should be used with appropriate mask and
breathing apparatus in areas of poor ventilation
and/or air flow.
FIRST AID
Swallowed: Give water to clean mouth. Do not induce
vomiting.
Skin: Remove contaminated clothing. Wash skin
thoroughly with soap and water.
Eyes: Hold open and flood with water for at least
15 minutes. Inhalation: Remove patient to fresh air.
If breathing is difficult administer oxygen.
Seek medical attention promptly.
SUBSTRATE VENTILATION
Substrate ventilation should be used to release moisture
trapped under the Butynol. Substrate ventilators are used
for this purpose. One way substrate ventilators prevent
moisture vapour build up and one should be installed every
90 square metres. Not designed to ventilate roof cavities.
ARDEX PRESSURE SEAL
Designed to seal the edges of ARDEX Butynol or ARDEX
Torch Applied Bitumen Membranes and ARDEX SBS Self
Adhesive Membranes where no existing cavity flashing or
dampcourse has been installed.
PRODUCT DESCRIPTION
3 metre lengths of specially formed aluminium strip.
INSTALLATION
The ARDEX Pressure Seal is mechanically fixed through
the top edge of the membrane at 500mm intervals.
The uppermost edge of the strip is then sealed with
ARDEX Butynol Sealant along the profile provided.
PACKAGING
Packs containing 10 x 3 metre lengths.
ARDEX PROTECTION BOARD
ARDEX Protection Board is a fluted polyethylene board
designed to be used after the membrane installation
and prior to backfilling to protect the membrane from
mechanical damage during the backfilling operation.
SIZE
1800 X 1200mm fluted boards.
PACKAGING
Packs of 25 boards.
Reviews
There are no reviews yet.